Skip to main content
HVAC & cleanroom

HVAC & Cleanroom Energy Optimisation

A better energy balance between comfort and compliance

Load-prediction-based chiller and AHU optimisation balancing cleanroom conditions and operating cost.

Equipment operation driven by actual load rather than fixed rulesPhased savings with fallback-safe designCoordinated optimisation of plant, distribution and terminals

SOLUTION ELEMENTS

Industry
HVAC & cleanroom
Products
3 systems
Delivery
Design · build · install · commission

Context

Central plant systems often run far below design load, with fixed-speed pumps and fans, suboptimal equipment staging and experience-based management—resulting in avoidable energy use. Cleanrooms add temperature, humidity, pressure and air-change constraints, making savings more complex.

Sub-metering, equipment modelling and optimised control identify and release savings while maintaining cleanroom conditions.

Requirements

  • Maintain stable cleanroom temperature, humidity and pressure
  • Reduce chiller, pump and AHU energy consumption
  • Automated equipment rotation and fault changeover
  • Preserve existing process and HVAC safety boundaries
  • Provide measurable energy-saving evaluation

Our approach

The system collects chiller, pump, cooling tower, AHU and terminal data and uses outdoor weather and indoor load predictions to adjust staging and setpoints. Chilled water is optimised by pressure/Delta-T, cooling towers by wet-bulb conditions, and AHUs adjust dampers and valves based on pressure and particle data.

Safety assurance

Optimisation algorithms are bounded by operating limits with manual override. On critical equipment faults, pressure excursions or fire signals, the system exits optimisation immediately and executes safety strategies.

HVAC & Cleanroom Energy Optimisation - project image 1
HVAC & Cleanroom Energy Optimisation - project image 2

System architecture

The existing BA control layer is retained while an optimisation server and energy analytics module read data and write setpoints through a gateway, avoiding direct disturbance of underlying control logic.

  • Equipment: chillers, pumps, towers, AHUs, valves and sensors
  • Control: DDC/PLC and safety interlocks
  • Optimisation: load prediction, equipment models, algorithms
  • Presentation: BMS graphics, energy dashboards and savings reports
HVAC & Cleanroom Energy Optimisation system architecture
SYSTEM ARCHITECTURE REFERENCE

Advantages

01

Equipment operation driven by actual load rather than fixed rules

02

Phased savings with fallback-safe design

03

Coordinated optimisation of plant, distribution and terminals

04

Transparent energy data for continuous improvement

05

Cleanroom compliance requirements considered throughout

Outcomes

Equipment staging and strategy optimisation establish a verifiable energy baseline and ongoing savings tracking. Actual savings depend on load profile, equipment condition and operating constraints, confirmed through trial-operation data.

START A PROJECT

The next system starts with a high-quality conversation.

Tell us about your process, site and objectives. Our engineering team will respond within one business day.

DIRECT CONTACT

kfj77@163.comTechnical support & FAQs

OFFICE HOURS

Mon–Fri, 09:00–18:00 (CST)