Water systems

Smart Water & Wastewater Treatment Control

An integrated digital foundation from process control to operations decisions

Covering the brochure process train—influent, screening, pumping, oxidation ditch, clarifiers, disc filtration and disinfection—with redundant PLCs, distributed I/O and conditioned analyser data feeding control and reporting.

Brochure process order from influent to effluent, including blowers, return sludge and tertiary treatmentEnergy metering at the panel: LV incomers, compensation panels, drives and soft startersThree access levels with operator and alarm changes stored in a separate database

SOLUTION ELEMENTS

Industry
Water systems
Products
4 systems
Delivery
Design · build · install · commission

Context

The difficulty in water and wastewater plants is rarely a single unit—it is the coupling across the train: fluctuating influent loads, drifting analyser readings, pumps and aeration run on experience, and regulatory reports assembled by hand. Retrofits add another constraint: outage windows are short and the legacy system must run in parallel for a period.

This solution links process, equipment, energy and compliance records into one data model and allows staged cut-over: monitoring first, control later, with a way back to the previous mode at every stage.

Requirements

  • Coverage from coarse screening to effluent, including sludge dewatering, dosing and odour control
  • Online analysers with sample conditioning, cleaning and calibration; abnormal data can be flagged
  • Pumps, aeration and dosing adjusted to process targets with manual override
  • Regulatory daily, monthly and annual reports plus operating ledgers generated automatically
  • Retrofit without stopping production; parallel running and staged cut-over
  • Multi-site supervision with local autonomy during network outages

Our approach

Control follows the brochure process order: influent, coarse screening, pumping station, fine screening, biological tank (oxidation ditch), secondary clarifiers, tertiary treatment (disc filtration), disinfection and effluent, with branch systems for aerobic blowers, return sludge, sludge dewatering, dosing and odour control included by project scope. Graphics follow the process flow rather than a list of equipment.

Control architecture

Redundant PLCs form the control core, with I/O distributed by process area. The main station and field stations communicate over industrial Ethernet, and fibre rings connect separate structures. A single failure does not stop other process areas; pump, valve, mixer, blower and dosing circuits retain local manual control and safety interlocks, with interlock conditions visible on screen and trip times logged.

Analysers and data quality

COD, ammonia, total phosphorus, total nitrogen, pH, dissolved oxygen, MLSS, flow and level analysers connect to one system. Sampling includes conditioning, filtration and backflush cleaning with scheduled calibration; out-of-range values, communication loss or expired calibration flag the data as invalid so it never enters reports. Sludge-concentration and dissolved-oxygen instrument boxes, probe positions and anti-clogging sample lines follow the brochure's site practice.

Operation and energy

Pumps rotate on level and flow trends with variable-speed units kept in their efficient range; aeration is staged on dissolved oxygen and influent load; dosing follows flow and effluent targets. Electrical parameters from LV incoming panels, capacitor compensation panels, drives and soft starters are collected to calculate energy and chemical consumption per process area and build a comparable operating baseline.

Data security and compliance reporting

Three access levels are provided and every login is written to the database. Operator actions and alarm changes are stored in a separate database rather than the runtime database. Daily, monthly and annual reports and ledgers are configured to the local environmental regulator's format, and values trace back to a tag and timestamp.

Construction and retrofit

Cable-trench wiring separates power and signal, pulls long runs first and avoids mid-run joints. Retrofits proceed in stages—monitor, then control, then optimise—with rollback switches and the legacy operating path retained, while wiring and loop checks are completed inside the outage window.

Smart Water & Wastewater Treatment Control - project image 2
Smart Water & Wastewater Treatment Control - project image 3

PROCESS COVERAGE

  1. 01Influent
  2. 02Coarse screening
  3. 03Pumping
  4. 04Fine screening
  5. 05Oxidation ditch
  6. 06Clarifiers
  7. 07Disc filtration
  8. 08Disinfection
  9. 09Effluent
BRANCH SYSTEMSAerobic blowersReturn sludgeSludge dewateringChemical dosingOdour control

System architecture

The system is layered into field, control, edge, platform and management tiers. The production control network is physically separated from the management network, and cross-tier data flows one way through edge nodes.

  • Field: online analysers, pumps, valves, drives, distribution and video
  • Control: redundant PLCs, distributed I/O, local stations and safety interlocks
  • Edge: protocol conversion (PROFINET / Modbus TCP / OPC UA), buffering and store-and-forward
  • Platform: SCADA supervision, alarms and historian
  • Management: multi-site operations, compliance reporting and mobile inspection

Interface boundaries: PLCs connect over industrial Ethernet; analysers use 4–20 mA, Modbus or PROFIBUS; data exchange with the group platform is read-only, and control commands are never issued across the network boundary.

Advantages

01

Brochure process order from influent to effluent, including blowers, return sludge and tertiary treatment

02

Energy metering at the panel: LV incomers, compensation panels, drives and soft starters

03

Three access levels with operator and alarm changes stored in a separate database

04

Reports and ledgers configured to the local regulator's format and ready to submit

05

Sludge and DO instrument boxes plus sample lines laid out to field practice, reducing clogging and drift

06

Power and signal separated, long runs first, no mid-run joints, staged retrofit with rollback

Outcomes

After handover, operators patrol and act from a single process graphic, energy and chemical consumption are traceable by process area, reports and ledgers follow the regulator's format, and operator actions and alarm changes remain independently auditable. Effluent stability and energy per cubic metre are confirmed from site data during commissioning and trial operation, not promised as fixed figures.

START A PROJECT

The next system starts with a high-quality conversation.

Tell us about your process, site and objectives. Our engineering team will respond within one business day.

DIRECT CONTACT

kfj77@163.comTechnical support & FAQs

OFFICE HOURS

Mon–Fri, 09:00–18:00 (CST)